# SDR ASOA201102388

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 19, 2011
- Submitted: December 22, 2011
- Operation: Air carrier
- Aircraft: [N844AS](https://openairdocs.org/aircraft/N844AS), registered now
- Make and model: Cndair CL6002B19
- Aircraft serial: 7317
- Aircraft time: 29,668 hours, 26,254 cycles
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Floor Support
- Condition: Corroded
- Location: Cabin
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ASOA201102388

## Discrepancy

CABIN FLOOR SUPPORT HAS CORROSION AT FLOOR PANEL.   REMOVED FLOOR SUPPORT IAW SRM 51-42-06, CORROSION EXCEEDS ALLOWABLE DAMAGE IAW SRM 53-00-00.   INSTALLED NEW FLOOR SUPPORT IAW SRM 51-20-11 & 51-42-06.  REPAIR IS CLASSIFIED AS A MAJOR REPAIR.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.