# SDR ASOA2011CL009

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 3, 2011
- Submitted: December 5, 2011
- Operation: Air carrier
- Aircraft: N14998
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 145302
- Aircraft time: 27,052 hours, 20,484 cycles
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Clamp
- Part number: NM1024200200
- Condition: Loose
- Location: Nr 1 Bleed Sys
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ASOA2011CL009

## Discrepancy

THE CREW REPORTED A NR 1 BLEED LEAK MESSAGE IN FLIGHT. THE ACFT DIVERTED AND LANDED WITHOUT INCIDENT.  MX INSPECTED AND TIGHTENED THE V-BAND CLAMP ON THE NR1 BLEED VALVE. OPS CHECKS WERE GOOD.

---