# SDR ASOA201201678

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: May 24, 2012
- Submitted: May 25, 2012
- Operation: Air carrier
- Aircraft: [N138EV](https://openairdocs.org/aircraft/N138EV), registered now
- Make and model: Cndair CL6002D24
- Aircraft serial: 15235
- Aircraft time: 8,255 hours, 5,462 cycles
- System (JASC): [2613 · Overheat Detection](https://openairdocs.org/jasc/2613)
- Part: Overheat Loop
- Condition: Out Of Position
- Location: Right
- Stage of operation: CL
- How discovered: O
- Nature of condition: N
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ASOA201201678

## Discrepancy

RT BLEED DUCT OVERHEAT WARNING.  EMERGENCY DECLARED.    FOUND BOTH LOOPS PRESSED INTO THW DUCTING COVERS.  CORRECTLY POSITIONED BOTH LOOPS IAW AMM 36-21-03.  PERFORMED BLEED LEAK DETECTION TEST IAW AMM 36-21-00, LOOPS OPERATE CORRECTLY, PERFORMED EXTENSIVE INSP FOR ANY ACTUAL BLEED LEAKS, NO LEAKS COULD BE FOUND IN THE BLEED SYS IN THE AFT EQUIPMENT AREA.

---