# SDR ASOA20140706089

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 6, 2014
- Submitted: July 7, 2014
- Operation: Air carrier
- Aircraft: [N11565](https://openairdocs.org/aircraft/N11565), registered now
- Make and model: Emb EMB-145LR
- Registry model: [EMB EMB-145LR](https://openairdocs.org/model/embraer-emb-145lr) (OpenAirDocs)
- Aircraft serial: 145621
- Aircraft time: 29,458 hours, 22,653 cycles
- System (JASC): [3040 · Windshield/Door Rain/Ice Removal](https://openairdocs.org/jasc/3040)
- Part: Controller
- Part number: 3801D2C
- Part serial: 1383
- Condition: Melted
- Location: Temp
- Part time: 16,602 hours, 14,972 cycles
- Stage of operation: NR
- How discovered: O
- Nature of condition: M, B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ASOA20140706089

## Discrepancy

THE CREW REPORTED A STRONG SMOKE ODOR, CIGARETTE & PAPER ODOR EMITTING FROM MCD, F/A JUMPSEAT, AROUND EQUIPMENT CLOSET.  THE ACFT RETURNED, WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE ACFT AND FOUND THE NR 1 WINDSHIELD TEMP CONTROLLER TO HAVE MELTED TERMONAL LUGS.  MAINTENANCE R & R THE AFFECTED WINDSHIELD TEMP CONTROLLER, OPS TESTED WITH NO DEFECTS, ANDTHE ACFT WAS APPROVED FOR RETURN TO SERVICE.

---