# SDR ASOA2014112411721

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 18, 2014
- Submitted: November 24, 2014
- Operation: Air carrier
- Aircraft: [N723EV](https://openairdocs.org/aircraft/N723EV), registered now
- Make and model: Cndair CL6002C10
- Aircraft serial: 10132
- Aircraft time: 26,550 hours, 18,685 cycles
- System (JASC): [2913 · Hydraulic Pump (Electric/Engine), Main](https://openairdocs.org/jasc/2913)
- Part: Pump
- Part number: 6619005
- Part serial: K0117A
- Condition: Leaking
- Location: Hydraulic Sys
- Stage of operation: CR
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/ASOA2014112411721

## Discrepancy

NR 1 HYD QUANTITY EVACUATED IN FLIGHT TO 0 PERCENT.  EDP RAN 1 HOUR 1 MIN W/OUT FLUID,  EMERGENCY DECLARED AS A PRECAUTION.  R & R LT ENGINE HYD PUMP IAW AMM 29-11-01, REF AIPC 29-11-01, ITEM 5.  OPS AND LEAK CHECKS GOOD AT THIS TIME.  ACFT RETURNED TO SERVICE.  SDR CLOSED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.