# SDR AU960222

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 1, 1996
- Submitted: March 26, 2000
- Operation: General aviation
- Make and model: Bnorm BN2A26
- Engine: Lyc O540E4C5
- System (JASC): [7414 · Magneto/Distributor](https://openairdocs.org/jasc/7414)
- Part: Magneto
- Part number: 103493108
- Condition: Contam Water
- Location: Elec Pwr Supply
- Component: Bendix, 103493108
- Stage of operation: TO
- Nature of condition: E, R
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/AU960222

## Discrepancy

(AUS) RH ENGINE RH MAGNETO FAULTY - INVESTIGATION FOUND WATER  CONTAMINATION SUSPECT CAUSED BY BLOCKAGE OF GAUZE SCREEN

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.