# SDR AUS20030002

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 1, 2003
- Submitted: February 10, 2003
- Operation: Air carrier
- Make and model: Swrngn SA227*
- Engine: Garrtt TPE33112UHR
- System (JASC): [7330 · Engine Fuel Indicating System](https://openairdocs.org/jasc/7330)
- Part: Line
- Part number: 2764024117
- Condition: Broken
- Location: Fuel Indicator
- Part time: 10,510 cycles
- Stage of operation: CR
- How discovered: O
- Nature of condition: E, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/AUS20030002

## Discrepancy

(AUS) RT ENGINE FUEL BYPASS WARNING LIGHT ILLUMINATED. INVESTIGATION FOUND THAT THE FUEL LINE TO THE DIFFERENTIAL PRESSURE TRANSMITTER WAS BROKEN AT THE CONNECTOR END FITTING.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.