- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 25, 1996
- Submitted: March 26, 2000
- Operation: Air carrier
- Aircraft: [N308AW](https://openairdocs.org/aircraft/N308AW), registered now
- Make and model: Boeing 737-3G7
- Registry model: [Boeing 737-3G7](https://openairdocs.org/model/boeing-737-3g7) (OpenAirDocs)
- Aircraft serial: 24710
- System (JASC): [5315 · Fuselage Main, Floor Beam](https://openairdocs.org/jasc/5315)
- Part: Floorbeam
- Condition: Corroded
- Location: Bs 967
- Stage of operation: IN
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/AWXA9600733

## Discrepancy

DURING ROUTINE MAINTENANCE CHECK, FOUND FLOORBEAM BS 967, WL 208, LBL 44 TO 55 CORRODED.  INSTALLED REPLACEMENT T-CAP ON FLOORBEAM AND FASTENERS FROM BS 967, WL 208, LBL 44 TO 55 PER SRM 51-40-02.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.