# SDR C2XA08CL133

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 17, 2008
- Submitted: December 18, 2008
- Operation: Air carrier
- Aircraft: [N11176](https://openairdocs.org/aircraft/N11176), registered now
- Make and model: Emb EMB-145XR
- Registry model: [EMB EMB-145XR](https://openairdocs.org/model/embraer-emb-145xr) (OpenAirDocs)
- Aircraft serial: 14500881
- Aircraft time: 11,012 hours, 6,183 cycles
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Valve
- Part number: 8166102
- Part serial: 2004040753
- Condition: Faulty
- Location: Nr 1
- Part time: 11,012 hours, 6,183 cycles
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/C2XA08CL133

## Discrepancy

CLE FLIGHT NR 2986 THE CREW REPORTED A BLEED 1 OVER TEMP WARNING DURING CLIMB IN ICING CONDITIONS.  THE ACFT RETURNED TO CLE AND LANDED WITHOUT INCIDENT.  MX INSPECTED AND REPLACED THE NR 1 FAN AIR VALVE.  OPS CHECKS WERE GOOD.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.