# SDR C2XA09CL097

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 17, 2009
- Submitted: July 20, 2009
- Operation: Air carrier
- Aircraft: [N11191](https://openairdocs.org/aircraft/N11191), registered now
- Make and model: Emb EMB-145XR
- Registry model: [EMB EMB-145XR](https://openairdocs.org/model/embraer-emb-145xr) (OpenAirDocs)
- Aircraft serial: 14500935
- Aircraft time: 10,853 hours, 5,769 cycles
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Precooler
- Part number: 14530609401
- Part serial: 0252
- Condition: Faulty
- Location: Nr2 Pylon
- Part time: 16,143 hours, 11,878 cycles
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/C2XA09CL097

## Discrepancy

CREW REPORTED A "BLEED 2 OVERTEMP" MESSAGE CLIMBING THRU 170000.  ACFT DIVERTED AND LANDED WITHOUT INCIDENT.  MX INSPECTED AND REPLACED THE NR2 ENGINE PRECOOLER ASSEMBLY. OPERATIONAL CHECKS WERE GOOD.

---