# SDR C2XA09RI204

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 7, 2009
- Submitted: December 16, 2009
- Operation: Air carrier
- Aircraft: [N11140](https://openairdocs.org/aircraft/N11140), registered now
- Make and model: Emb EMB-145XR
- Registry model: [EMB EMB-145XR](https://openairdocs.org/model/embraer-emb-145xr) (OpenAirDocs)
- Aircraft serial: 145732
- Aircraft time: 18,845 hours, 9,972 cycles
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Filter
- Part number: 8166015
- Condition: Clogged
- Location: Fan Air Valve
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/C2XA09RI204

## Discrepancy

FLIGHT 2524 - RIC - FLIGHT CREW REPORTED THAT AFTER ENTERING ICING DURING T/O, FIRST GOT PACK 2 OVERHEAT, THEN GOT BLEED 1 OVERHEAT, THEN GOT BLEED 2 OVERHEAT.  FLIGHT CREW DIVERTED FLIGHT TO RIC AND LANDED ACFT UNEVENTFULLY.  RIC MX REMOVED AND REPLACED FAN AIR VALVE FILTER AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY.  ACFT WAS APPROVED TO RETURN TO SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.