# SDR C77A201202180011

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 14, 2012
- Submitted: February 18, 2012
- Operation: Air carrier
- Aircraft: N619CZ
- Make and model: Emb ERJ 170-200 LR
- Registry model: [EMB ERJ 170-200 LR](https://openairdocs.org/model/embraer-s-a-erj-170-200-lr) (OpenAirDocs)
- Aircraft serial: 17000213
- Aircraft time: 10,674 hours, 6,210 cycles
- System (JASC): [5321 · Fuselage Floor Panel](https://openairdocs.org/jasc/5321)
- Part: Floor Panel
- Part number: 17091919001
- Condition: Corroded
- Location: Zone 200
- Part time: 10,674 hours, 6,210 cycles
- Stage of operation: IN
- How discovered: V
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/C77A201202180011

## Discrepancy

AFT CABIN RIGHT FLOOR PANEL, AT FR 87 IS CORRODED BEYOND SRM LIMITS.  R & R RT FLOOR PANEL IAW SRM 51-41-02 AND 51-43-02 ON WO 452281-277 IAW EO E175-5300-045,  WO 517415.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.