# SDR CA000501031

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 7, 2000
- Submitted: January 19, 2001
- Operation: General aviation
- Make and model: Doug DC-9-32
- Registry model: [Doug DC-9-32](https://openairdocs.org/model/mcdonnell-douglas-dc-9-32) (OpenAirDocs)
- Aircraft time: 77,201 hours
- Engine: Pwa JT8D7
- System (JASC): [2450 · AC Power Distribution System](https://openairdocs.org/jasc/2450)
- Part: Connector
- Part number: 5256
- Condition: Contaminated
- Location: Emergency Exit
- Stage of operation: IN
- How discovered: C
- Nature of condition: B
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA000501031

## Discrepancy

(CAN) SMOKE IN CABIN.  AC OUTLET ARCING AND SMOKING AT FLOOR LEVEL UNDERNEATH LT OVERWING EMERGENCY EXIT. WATER INFILTRATION IN CONNECTOR FROM OVERWING EXIT. CONNECTOR REPLACED.  (ADP)

---