# SDR CA001031016

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 26, 2000
- Submitted: January 19, 2001
- Operation: General aviation
- Make and model: Dhav DHC8301
- System (JASC): [2720 · Rudder Control System](https://openairdocs.org/jasc/2720)
- Part: Pressure Switch
- Part number: 7G772
- Condition: Failed
- Location: Rudder Damper
- Part time: 12 hours
- Stage of operation: TX
- How discovered: O
- Nature of condition: N
- Precautionary procedure: D
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA001031016

## Discrepancy

(CAN) BWIA MCC REPORT FROM GEORGETOWN, BARBADOS: NR 2 RUDDER HYDRAULIC CAUTION LIGHT ILLUMINATED (SWITCHES SWAPPED FOR TROUBLESHOOTING), PROBLEM TRANSFERRED TO NR 1 SIDE. NR 1 PRESSURE SWITCH ON RUDDER DAMPER REPLACED (SWITCH WAS SWAPPED).AIRCRAFT FUNCTIONALLY TESTED SATISFACTORY, RETURN TO SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.