# SDR CA031017005

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 17, 2003
- Submitted: November 3, 2003
- Operation: General aviation
- Make and model: Bombdr DHC8400
- Engine: Pwc PW150A
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Battery Pack
- Part number: 6050251
- Part serial: 0613
- Condition: Shorted
- Location: Emergency Light
- Stage of operation: NR
- How discovered: O
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA031017005

## Discrepancy

(CAN) DURING TROUBLE SHOOTING OF A CONTINUOUS POPPING OF CIRCUIT BREAKER G3 (EMERG LTS) HAS BEEN REPORTED. INVESTIGATION SHOWED BURNED WIRING AT EMERGENCY LIGHT POWER SUPPLY BOX EPS4, FROM CONNECTOR 3351-P6.  THERE WAS SIGNS OF AN INTERNAL SHORT INSIDE BATTERY PACK.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.