# SDR CA031114001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 6, 2003
- Submitted: January 5, 2004
- Operation: General aviation
- Make and model: Cndair CL6002C10
- Engine: Ge CF348C1
- System (JASC): [2820 · Aircraft Fuel Distribution System](https://openairdocs.org/jasc/2820)
- Part: Ejector
- Part number: T99A378603
- Part serial: A71939
- Condition: Cracked
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA031114001

## Discrepancy

(CAN) FUEL WAS TRANSFERRING FROM THE RT TANK TO THE CENTER TANK.  THE TRANSFER WAS NOTICED WHILE THE A/C WAS ON GROUND.  INVESTIGATION REVEALED THAT THE RT PRIMARY EJECTOR WAS CRACKED AND THE FUEL WAS LEAKING FROM THE EJECTOR TO THE CENTER TANK.  THE EJECTOR WAS REPLACED AND A/C RETURNED TO SERVICE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.