# SDR CA031208007

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 28, 2003
- Submitted: January 5, 2004
- Operation: General aviation
- Make and model: Doug DC-9-83
- Registry model: [Doug DC-9-83](https://openairdocs.org/model/douglas-dc-9-83) (OpenAirDocs)
- Engine: Pwa JT8D219
- System (JASC): [3080 · Ice Detection](https://openairdocs.org/jasc/3080)
- Part: Augment Valve
- Part number: 39271012
- Condition: Failed
- Location: Right
- Component: Ice Detection
- Stage of operation: CL
- How discovered: O
- Nature of condition: J, M
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA031208007

## Discrepancy

(CAN) RT ICE PROTECTION TEMPERATURE HIGH ILLUMINATED IN CLIMB. AIRCRAFT LANDED. MAINTENANCE REPLACED THE RT AUGMENTATION VALVE P/N 392710-2, S/N 3798 AND THE RT ICE ANTICIPATORS P/N 129110-2-1, S/N P118 AND P/N 129112-1-1, S/N N4216. SYSTEM WAS SERVICEABLE FOLLOWING THESE ACTIONS.

---