# SDR CA070425003

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 19, 2007
- Submitted: June 7, 2007
- Operation: General aviation
- Make and model: Bombdr DHC8400
- Engine: Pwc PW150A
- Propeller: Rotol CR4086123F17
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Generator
- Part number: 11522184
- Part serial: 062C0420
- Condition: Lack Of Lube
- Location: Nr 1
- Part time: 3,760 hours
- Stage of operation: AP
- How discovered: O
- Nature of condition: G, J
- Precautionary procedure: E
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA070425003

## Discrepancy

(CAN) DURING APPROACH TO BASE AT 1000 FEET, THE NR 1 AC GENERATOR CAUTION LIGHT ILLUMINATED. PILOT CYCLED THE NR 1 AC GENERATOR AND THEN THE AC GENERATOR HOT CAUTION LIGHT ILLUMINATED AS WELL AS THE AC GENERATOR CAUTION LIGHT.  AFTER TOUCHDOWN WHEN PLA RETARDED TO DISC THE NR 1 OIL PRESS WARNING LIGHT ILLUMINATED AND THE ENGINE WAS SHUTDOWN.  GROUND INSPECTION REVEALED: AC GEN OVERHEATED, AC GEN QUILL SHAFT SEPARATED, NO OIL ON THE SIGHT GAGE, NO EXTERNAL LEAK, METAL TRAPPED ON THE AC GEN MCD 41 SEC, LOW OIL PRESS EXCEEDED, RECORDED IN EMU.  NR 1 ENGINE REPLACED DUE TO THE EXCEEDING. (TC NR 20070425003)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.