# SDR CA071017001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 16, 2007
- Submitted: October 24, 2007
- Operation: General aviation
- Make and model: Bombdr BD1001A10
- Engine: Hnywl AS90711A
- System (JASC): [2434 · DC Generator-Alternator](https://openairdocs.org/jasc/2434)
- Part: Generator
- Part number: A3579101
- Condition: Failed
- Location: Right
- Part time: 330 hours
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA071017001

## Discrepancy

(CAN) IN CRUISE FLIGHT RT GENERATOR FAILED. AFTER FOLLOWING PROCEDURES A/C LANDED WITHOUT ANY MORE INCIDENT. TROUBLESHOOTING WITH MDC REPORTED PCB6 AT FAULT FROM GCU P/N R608-003. FURTHER TROUBLESHOOTING REVEALED RT GENERATOR WAS AT FAULT NOT THE GCU. GENERATOR WAS REMOVED AND REPLACED AND A/C RETURNED TO SERVICE. NORMAL TBO FOR GENERATOR IS 3000 HRS GENERATOR HAD ONLY 329.7 HRS. MANUFACTURER OF GENERATOR IS AUXILEC (F0296) TAKEN ON DATA PLATE. (TC NR20071017001)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.