# SDR CA091120001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 17, 2009
- Submitted: January 19, 2010
- Operation: General aviation
- Make and model: Bombdr DHC8400
- Engine: Pwc PW150A
- System (JASC): [2841 · Fuel Quantity Indicator](https://openairdocs.org/jasc/2841)
- Part: Probe
- Part number: 028069109
- Condition: Malfunctioned
- Location: Fuel Tank
- Part time: 10,520 hours
- Stage of operation: AP
- How discovered: O
- Nature of condition: N
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA091120001

## Discrepancy

(CAN) ON CRUISE NR 2 TANK FUEL LOW, CAUTION LIGHT ILLUMINATED, FUEL INDICATOR WAS ERRATIC WITH READING OF DASHES.  ON FINAL APPROACH FOR LANDING ABOUT 8 MILES, ENG NR 2 FLAME OUT.  MAINTENANCE ACTION, PERFORMED FUNCTIONAL TEST OF THE FUEL CONTROL ELECTRICAL WIRING HARNESS IAW AMM TASK 73-21-11.720.80, OK PERFORMED FUEL QUANTITY CHECK OF LT AND RT FUEL TANKS USING MAGNA STICK IAW AMM TASK 28.40.26.610.801 RESULTS: LT 769 KG. RT NIL PERFORMED FIM TASK NR 28-40.00.810.827 FOUND TANK PROBE NR 9 FAULTY. (TC NR 20091120001)

---