# SDR CA110323003

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 22, 2011
- Submitted: September 14, 2015
- Operation: General aviation
- Make and model: Emb ERJ 190-100 IGW
- Registry model: [EMB ERJ 190-100 IGW](https://openairdocs.org/model/embraer-erj-190-100-igw) (OpenAirDocs)
- Aircraft time: 9,721 hours
- Engine: Ge CF3410E5A1
- System (JASC): [2100 · Air Conditioning System](https://openairdocs.org/jasc/2100)
- Part: Controller
- Condition: Malfunctioned
- Location: Ams
- Stage of operation: CR
- How discovered: O
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA110323003

## Discrepancy

(CAN) EN-ROUTE, THE ACFT EXPERIENCED A NR 1 BLEED LEAK.  THE ACFT DESENDED TO FL200. IN CONSULTATION WITH FLIGHT DISPATCH, THE FLIGHT PLAN WAS RECALCULATED WITH THE ACFT BEING ABLE TO CONTINUE ONTO ORIGINAL STATION.  FAULT CODE 36215007AM1 FOUND.  PERFORMED TSM TASK 36-21-00-810-801-A, REPLACED AMS CONTROLLER 1 SLOT 18 IAW AMM 21-00-01-000-801-A & 21-00-01-400-801-A.  TESTS SERVICEABLE.  AMS CONTROLLER 1 REMOVED PN 1001050-2-009, SN PR06032920.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.