## Discrepancy

(CAN) AMBER NLG, DOOR & RED NOSE LIGHTS REMAINED ILLUMINATED AFTER GEAR SELECTED UP.  FOUND THE NLG DOORS DAMAGED.  REPLACED SOLENOID SEQUENCE VLV & MECHANICAL SEQUENCE VLV.  RIGGING CHECK ALL NLG SENSORS.  ADJUSTED NLG DOOR & NGDN1 SENSOR.  REPLACED GEAR DOORS.  SEE ALSO FAA SDR 2011110500012 QXEA2011101201009.

---