# SDR CA120210005

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 8, 2012
- Submitted: September 14, 2015
- Operation: General aviation
- Make and model: Cndair CL6002B19
- System (JASC): [5210 · Passenger/Crew Doors](https://openairdocs.org/jasc/5210)
- Part: Door
- Part number: TBD
- Condition: Out Of Adjust
- Location: Main Pax
- Stage of operation: DE
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA120210005

## Discrepancy

(CAN) DURING DESCENT, THE PASSENGER DOOR INDICATION WAS ILLUMINATED AND THE INTERNAL PRESSURE WAS OSCILLATING.  FLIGHT CREW DECIDED TO CONTINUE FLIGHT TO DESTINATION AIRPORT.  GAP BETWEEN PROXIMITY SENSOR AND DOOR WAS FOUND OUT OF LIMITS. THEY ALSO FOUND FROZEN WATER IN SEALANT.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.