# SDR CA120312027

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 8, 2012
- Submitted: September 14, 2015
- Operation: General aviation
- Make and model: Emb ERJ 190-100 IGW
- Registry model: [EMB ERJ 190-100 IGW](https://openairdocs.org/model/embraer-erj-190-100-igw) (OpenAirDocs)
- Aircraft time: 16,572 hours
- Engine: Ge CF3410E5A1
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Valve
- Part number: 10070863
- Condition: Failed
- Location: Bleed System
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: B, A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA120312027

## Discrepancy

(CAN)   BLEED 2 FAILED DURING CLIMB,  EMERGGENCY  DESCENT TO 5000 FT, RETURNED TO STATION.  RT PACK INLET TEMP SENSOR REPLACED IAW AMM 21-51-17.  RT FAN AIR VALVE AND BELLOW REPLACED IAW AMM 36-11-09 PB401.

---