# SDR CA120628009

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 27, 2012
- Submitted: September 14, 2015
- Operation: General aviation
- Make and model: Cndair CL6002B19
- Engine: Ge CF343B1
- System (JASC): [4930 · APU Engine Fuel and Control](https://openairdocs.org/jasc/4930)
- Part: Line
- Part number: 38849671
- Condition: Cracked
- Location: Vg Actuator
- Part time: 5,285 hours
- Stage of operation: AP
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA120628009

## Discrepancy

(CAN) APU HAD HIGH ITT ON START, HIGH ITT WHEN AIR CONDITIONING PACK AIR DEMAND APPLIED AND APU AUTO SHUTDOWN.  REMOVED APU AND FOUND THE COMPRESSOR DISCHARGE SENSE LINE, PN 3884967-1 TO THE VARIABLE GUIDE VANE ACTUATOR, PN 126842-2-1, BROKEN AT THE B-NUT FLAIR.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.