# SDR CA120706001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 21, 2012
- Submitted: September 14, 2015
- Operation: General aviation
- Make and model: Bombdr DHC8400
- Engine: Pwc PW150A
- Propeller: Rotol CR4086123F17
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Generator
- Part number: 11521062
- Condition: Failed
- Location: Nr 1
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA120706001

## Discrepancy

(CAN) DURING FLIGHT, THE CREW HAS NOTICED DC GEN NR 1 CAUTION LIGHT ON.  AFTER LANDING THE NR 1 DC GENERATOR AND ENGINE AREA WAS INSPECTED.  THE GENERATOR WAS FOUND TOTALLY DESTROYED.  ALSO THE WHOLE NACELLE WAS CONTAMINATED WITH GENERATOR PARTS.  REMOVED THE GENERATOR, CLEANED THE WHOLE ENGINE AND AREA AROUND INSPECTED ENGINE AND AREA.  NEW GENERATOR INSTALLED AMM 24-31-01-400-801.  LOWER COWLING REMOVED FOR CLEANING.  LOWER COWLING REINSTALLED AMM 71-10-16-400-801. OPS TEST OF DC GENERATION SYSTEM PERFORMED AMM24-31-00-710-802, FOUND SERVICEABLE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.