# SDR CA120907002

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 31, 2012
- Submitted: September 14, 2015
- Operation: General aviation
- Make and model: Bombdr DHC8400
- Engine: Pwc PW150A
- Propeller: Rotol CR4086123F17
- System (JASC): [7921 · Engine Oil Cooler](https://openairdocs.org/jasc/7921)
- Part: Actuator
- Part number: D2887355C
- Condition: Failed
- Location: Oil Cooler
- Part time: 4,540 hours
- Stage of operation: CR
- How discovered: O
- Nature of condition: M, J
- Precautionary procedure: E, A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA120907002

## Discrepancy

(CAN) NR 2 OIL TEMP CLIMBED TO 117.  CHECK LIST COMPLETED WITH AND TEMP REDUCED TO 114. IAW CHECK LIST, NR 2 ENGINE WAS SHUTDOWN.  ACFT LANDED.  ACOC THERMAL VALVE AND ACOC DOOR ACTUATOR REPLACED.  NO HISTORY ON THIS ACFT IN LAST 60 DAYS.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.