# SDR CA130702004

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 30, 2013
- Submitted: September 14, 2015
- Operation: General aviation
- Make and model: Emb ERJ 190-100 IGW
- Registry model: [EMB ERJ 190-100 IGW](https://openairdocs.org/model/embraer-erj-190-100-igw) (OpenAirDocs)
- Aircraft time: 16,655 hours
- Engine: Ge CF3410E5A1
- System (JASC): [3140 · Central Computers](https://openairdocs.org/jasc/3140)
- Part: Module
- Part number: 70253651901
- Condition: Failed
- Location: Central Computer
- Stage of operation: NR
- How discovered: O
- Nature of condition: O
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA130702004

## Discrepancy

(CAN) EMERGENCY DECLARED WITH ATC ACCOUNT OF BRIEF FIRE INDICATION.  NO SMOKE VISIBLE IN ACFT BUT CABIN TEMPERATURE INCREASING.  GENERIC O/O NR 3 REPLACED IAW AMM 31-41-06. CARGO HI-RATE BOTTLE REPLACED IAW AMM 26-23-01.  CARRIED OUT WIRING CHECK IAW WDM 26-23-50.  FOUND HIGH RESISTANCE ON GROUND STUD GS0287, 336 OHMS.  UPON INSPECTION FOUND GROUND STUD VERY LOOSE. TIGHTENED AND SECURED, RESISTANCE CHECK CONFIRMED GROUND GOOD. OPS TESTED IAW 26-23-01.  CHECK SERV.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.