# SDR CA140612004

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 1, 2014
- Submitted: March 12, 2015
- Operation: General aviation
- Make and model: Bombdr DHC8400
- Engine: Pwc PW150A
- Propeller: Rotol CR4086123F17
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Generator
- Part number: 11522186
- Condition: Failed
- Location: Nr 1 Ac
- Stage of operation: TO
- How discovered: O
- Nature of condition: J
- Precautionary procedure: C
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA140612004

## Discrepancy

(CAN) NR 1 AC GENERATOR CAUTION LIGHT ILLUMINATED JUST AFTER STARTING TAKEOFF ROLL THEN FLIGHT CREW REJECTED TAKEOFF.  THE CAUTION LIGHT DID NOT GO OFF BY RESET THE NR 1 AC GENERATOR SWITCH OFF THEN ON.  ENGINEER PERFORMED OPS TEST OF AC GENERATOR SYS AND CONFIRMED THE SNAG.  NR 1 AC GENERATOR DID NOT GO OFF AFTER ENGINE START & CONDITION LEVER TO MIN, NEVER ON-LINE NR 1 AC GENERATOR.  REPLACED NR 1 AC GENERATOR  AND OPS TEST OF AC GENERATOR WAS OK.  THE ACFT RETURNED TO SERVICE ON SAME DAY.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.