# SDR CA141110001

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 10, 2014
- Submitted: March 12, 2015
- Operation: General aviation
- Make and model: Bombdr DHC8400
- Engine: Pwc PW150A
- System (JASC): [2913 · Hydraulic Pump (Electric/Engine), Main](https://openairdocs.org/jasc/2913)
- Part: Pump
- Part number: 66173
- Condition: Failed
- Location: Hyd System
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA141110001

## Discrepancy

(CAN) AIR TURN BACK DUE TO CAPTAIN REPORTING NR 2 HYDRALIC CAUTION ALL PRESSURE AND QTY NORMAL.  AIRCRAFT RETURNED TO POINT OF DEPARTURE FOR AN UNEVENTFUL LANDING NO EMERGENCY WAS DECLARED THE NR 2 EDP FAILED, METAL FOUND IN CASE DRAIN FILTER. REPLACEMENT OF EDP AND HYDRAULIC FLUSHING IN PROGRESS.

---