# SDR CA150427003

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: April 26, 2015
- Submitted: August 5, 2015
- Operation: General aviation
- Make and model: Boeing 787-8
- Registry model: [Boeing 787-8](https://openairdocs.org/model/boeing-787-8) (OpenAirDocs)
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Line
- Condition: Leaking
- Location: Hydraulic Sys
- Stage of operation: NR
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA150427003

## Discrepancy

(CAN) CREW REPORTED LT HYD SYSTEM FLUID LOSS AND RETURNED.  RESOLUTION RT FLAPER ON POWER CONTROL UNIT RETURN LINE, LT HYD SYS, TIGHTENED IAW DMC B787-A-20-11-00-00A-030A-A.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.