# SDR CA150803003

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: August 2, 2015
- Submitted: April 22, 2016
- Operation: General aviation
- Make and model: Emb ERJ 190-100 IGW
- Registry model: [EMB ERJ 190-100 IGW](https://openairdocs.org/model/embraer-erj-190-100-igw) (OpenAirDocs)
- Aircraft time: 24,741 hours
- Engine: Ge CF3410E5A1
- System (JASC): [2913 · Hydraulic Pump (Electric/Engine), Main](https://openairdocs.org/jasc/2913)
- Part: Pump
- Part number: 5116404
- Condition: Failed
- Location: Hyd System
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA150803003

## Discrepancy

(CAN) AT APPROX 2315Z AC PATCHED THROUGH TO MOC VIA DISPATCH REGARDING LOSS OF THEIR NR 2 HYDRAULICS, WILL CONTINUE BUT WILL DECLARE AN EMERGENCY THROUGH ATC FOR THE ARRIVAL...TOWER CONTACTED AND STATION ORGANIZED A TOW TO GET AIRCRAFT OFF THE RUNWAY.  NR 2 HYD STSTEM PRESURE, RETURN AND BOTH CASE DRAIN FILTERS REPLACED AS PER AMM 29-00-01 HYD SYSTEM DECONTAMINATION PROCEDURE.  NR 2 ENG HYD EDP REPLACED AS PER AMM 29-11-01.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.