# SDR CA151116006

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 14, 2015
- Submitted: April 22, 2016
- Operation: General aviation
- Make and model: Emb ERJ 190-100 IGW
- Registry model: [EMB ERJ 190-100 IGW](https://openairdocs.org/model/embraer-erj-190-100-igw) (OpenAirDocs)
- Aircraft time: 21,423 hours
- Engine: Ge CF3410E5A1
- System (JASC): [2150 · Cabin Cooling System](https://openairdocs.org/jasc/2150)
- Part: Control Valve
- Part number: 10014566
- Condition: Failed
- Location: Ac Pack
- Stage of operation: CL
- How discovered: O
- Nature of condition: B
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA151116006

## Discrepancy

(CAN) ON TAKEOFF AND LANDING THERE WAS A BURNING ODOR DETECTED BY THE CREW. NO SIGN OF VISIBLE SMOKE. A PAN PAN WAS DECLARED. LOCAL MTCE IS INVESTIGATING.  RT PACK FLOW CONTROL VALVE, RT PACK BYPASS VALVE FILTERS REPLACED AS PER AMM 21-51-01 AND 21-51-00 RESPECTIVELY, AND LT AND RT RECIRCULATION AIR FILTERS REPLACED AS PER 21-24-02 PB 401.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.