# SDR CA151130008

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 27, 2015
- Submitted: April 22, 2016
- Operation: General aviation
- Make and model: Bombdr DHC8402
- Engine: Pwc PW150A
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Generator
- Condition: Failed
- Location: Ac System
- Stage of operation: AP
- How discovered: O
- Nature of condition: G
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA151130008

## Discrepancy

(CAN) JUST HAD A DOUBLE AC GENERATOR FAILURE ON APPROACH.  THE NR 1 EVENTUALLY RESET BUT FAILED AGAIN PRIOR TO LANDING.  THE NR 2 AC GENERATOR WOULD NOT RESET.  ACFT LANDED WITHOUT AC POWER IN ICING CONDITIONS. ENGINEERS HAVE SINCE GROUND RUN THE AIRCRAFT AND FUNCTIONED THE AC SYSTEM WITH ALL HEATERS ON AND PROP DE-ICING AND ARE UNABLE TO FAULT THE AC SYSTEM.  THE ENGINEERS WILL INSPECT BOTH PROPELLER BACK PLATES FOR THE BUS BAR CONDITION AND ALSO DROP THE FLAPS AND HAVE A LOOK AT THE WIRING ON THE REAR SPAR  ON SATURDAY IT HAD A NR 2 PROP DE-ICE CAUTION AND ONE DE-ICE HARNESS WAS BADLY DAMAGED, PROBABLY HAD CAUGHT IN THE SPINNER AT SOME TIME.  HARNESS WAS REPLACED. (TMCU WAS OK) SUSPECT A PROP HARNESS HAD AN INTERMITTENT SHORT WHICH MAY HAVE CAUSED THE DUAL AC GEN FAILURE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.