# SDR CA160219002

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 18, 2016
- Submitted: April 22, 2016
- Operation: General aviation
- Make and model: Cndair CL600*
- System (JASC): [2120 · Air Distribution System](https://openairdocs.org/jasc/2120)
- Part: Filter
- Part number: GG67095023
- Condition: Clogged
- Location: Cabin
- Stage of operation: CL
- How discovered: O
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA160219002

## Discrepancy

(CAN) PAX/CABIN CREW REPORTED SMOKE IN FWD LAV AREA, BURNING SMELL IN THE CABIN FROM FWD GALLEY TO SEAT ROW 25. T/S REVEALED COLLAPSED RT RECIRCULATION FILTER. NO OTHER ABNORMALITIES WERE FOUND/REPORTED. IT IS SUSPECTED THAT FILTER COLLAPSED DUE TO HEAVY CONTAMINATION & CLOGGING.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.