# SDR CA190329029

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 27, 2019
- Submitted: August 17, 2020
- Operation: General aviation
- Make and model: Cndair CL6002B19
- System (JASC): [5320 · Fuselage Miscellaneous Structure](https://openairdocs.org/jasc/5320)
- Part: Floor Support
- Part number: 601R31133
- Condition: Corroded
- Location: Cabin
- Part time: 29,149 hours
- Stage of operation: IN
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA190329029

## Discrepancy

(CAN) OPERATOR REPORTED (6) BLENDED CORROSION AREAS ON THE FLOOR SILL (DWG: 601R31133, 0.063  NOMINAL THICKNESS, REF) BETWEEN FS559.00+L6 AND FS559.00+48, RHS. DIMENSIONS ARE: ITEM #1: 6.0 L X 1.5 W X REMAININIG THICKNESS 0.062  ITEM #2: 4.0` L X 1.5 W X REMAININIG THICKNESS 0.042  ITEM #3: 2.0 L X I.0 W X REMAININIG THICKNESS 0.058  ITEM #4: 2.5 L X I.0 W X REMAININIG THICKNESS 0.047  ITEM #5: I.6 L X 1.0 W X REMAININIG THICKNESS 0.050  ITEM #6: 1.4 L X 0.9 W X REMAININIG THICKNESS 0.060   OPERATOR REPORTED (3) BLENDED CORROSION AREAS ON THE RH FLOOR SILL INTERCOSTAL M/C STA 559 - 559+16, E.C.S. OPTION (DWG: 601R38842, REF) WITH A MINIMUM OF REMAININIG THICKNESS 0.016 .  NOTE: THE RH FLOOR SILL INTERCOSTAL M/C STA 559 - 559+L6, E.C.S. OPTION (DWG: 60LR38842, REF) WILL BE REPLACED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.