# SDR CA190702013

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 1, 2019
- Submitted: August 17, 2020
- Operation: General aviation
- Make and model: Airbus BD-500-1A10
- Registry model: [Airbus BD-500-1A10](https://openairdocs.org/model/airbus-canada-ltd-ptnrsp-bd-500-1a10) (OpenAirDocs)
- System (JASC): [2430 · DC Generating System](https://openairdocs.org/jasc/2430)
- Part: Gcu
- Part number: C07500031007
- Condition: Failed
- Location: Rt Generator
- Stage of operation: NR
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA190702013

## Discrepancy

(CAN) SER - ETOPS - R/H GEN INOP  GEN INOP (GATE RETURN) O PREVIOUS RESET, NO FIX O AS PER EFIM, CHECKED CONNECTOR AT #2 GCU O RE-START CARRIED OUT WITH GEN FAULT WITH DISCONNECT LIGHT O FAULT CODE LEADS TO GCU INTERNAL FAULT (NO CODE SUPPLIED) O REPLACED RH GCU, AND FAULT CLEARED O PN C07500031-007, SN OFF 00324, SN ON 00060 (TC# 20190702013)

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.