## Discrepancy

(CAN) LEFT HYDRAULIC SHUTOFF VALVE SHOWS CLOSED ON THE SYNOPTIC PAGE AND WHITE WITH CYAN ICAS (L HYD SOV CLOSED) POSTED AND INTERMITTENT AMBER (L HYD TEMP HIGH) POSTING. NOTHING IN THE MDC BUT PSEU NVM LOGGING DIN#11. TEMPERATURE SWITCH (MT133) AND FIREWALL SHUTOFF VALVE ACTUATOR REPLACED. (TC# 20190711014)

---