# SDR CA190722013

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 20, 2019
- Submitted: August 17, 2020
- Operation: General aviation
- Make and model: Bombdr DHC8400
- Aircraft time: 6,901 hours
- System (JASC): [3097 · Ice/Rain Protection System Wiring](https://openairdocs.org/jasc/3097)
- Part: Relay
- Part number: MS24166D1
- Condition: Faulty
- Location: Anti-Ice Sys
- Stage of operation: CR
- How discovered: 9
- Nature of condition: O
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA190722013

## Discrepancy

(CAN) REPEATED STANDBY PITOT HEAT CAUTION IN FLIGHT, PITOT TUBE AND TMU WERE REPLACED BUT THE DEFECT RETURNED, MTC`S TROUBLESHOOTING INDICATE THAT TAPPING THE RELAY RECTIFIED THE FAULT. THE RELAY WERE PREVIOUSLY REPLACED 9 DAYS AGO. THE 3000-K5 RELAY WERE REPLACED AND THE STANDBY PITOT HEAT WERE TESTED WITH NO FURTHER FAULT NOTED. NO REPEATED FAULT NOTED TO DATE. (TC# 20190722013)

---