# SDR CA960417504

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: March 12, 1996
- Submitted: March 26, 2000
- Operation: Air carrier
- Make and model: Doug DC-9-32
- Registry model: [Doug DC-9-32](https://openairdocs.org/model/mcdonnell-douglas-dc-9-32) (OpenAirDocs)
- Engine: Pwa JT8D7A
- System (JASC): [2170 · Humidity Control System](https://openairdocs.org/jasc/2170)
- Part: Coalescer Bag
- Condition: Contaminated
- Location: Lt Air Cond
- Stage of operation: TX
- Nature of condition: B
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA960417504

## Discrepancy

(CAN)AFTER SELECTING LEFT AIR CONDITIONING SUPPLY SWITCH TO "HIGH BLEED OFF" ON GROUND WITH A.P.U. RUNNING, STRONG HEAT ODOUR DETECTED IN CABIN. MAINTENANCE CHANGED LEFT COALESCER BAG.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.