# SDR CA971125015

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: November 16, 1997
- Submitted: March 26, 2000
- Operation: Air carrier
- Make and model: Cndair CL6002B19
- Engine: Ge CF343A1
- System (JASC): [2611 · Smoke Detection](https://openairdocs.org/jasc/2611)
- Part: Detector
- Part number: PU9421R3
- Condition: Failed
- Location: Lavatory
- Part time: 3,303 hours
- Stage of operation: AP
- Nature of condition: N
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA971125015

## Discrepancy

(CAN) ON APPROACH, A TOILET SMOKE MESSAGE ON ENGINE INDICATION AND CREW ALERT SYSTEM WITH LAVATORY SMOKE DETECTOR ALARM ON.  SMOKE ODOR NOTICED, BUT NO SMOKE OR FIRE VISIBLE.  EMERGENCY RESPONSE VEHICLES CALLED OUT.  FLIGHT LANDED OK.  NO EVIDENCE OF SMOKE OR FIRE IN LAVATORY.  LAVATORY SMOKE DETECTOR REPLACED.  PART TC:  2,977.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.