# SDR CA971216026

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: December 3, 1997
- Submitted: March 26, 2000
- Operation: Air carrier
- Make and model: Doug DC-10-30
- Registry model: [Doug DC-10-30](https://openairdocs.org/model/mcdonnell-douglas-dc-10-30) (OpenAirDocs)
- System (JASC): [3030 · Pitot/Static Anti-Ice System](https://openairdocs.org/jasc/3030)
- Part: Controler
- Part number: 54211
- Condition: Failed
- Location: Pitot Heat
- Stage of operation: CL
- Nature of condition: J, L
- Precautionary procedure: O, A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA971216026

## Discrepancy

(CAN) PITOT HEAT INOPERATIVE, LIGHT ON DURING ROTATION.  CHECKLIST PERFORMED WITH NO CHANGE TO LIGHT INDICATIONS, 2-5 AMPS EXCEPT RIGHT STATIC WHICH SHOWED .1 AMP.  ALL CIRCUIT BREAKERS CHECKED.  PITOT HEAT CONTROLLER REPLACED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.