# SDR CA980402012

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: February 27, 1998
- Submitted: March 26, 2000
- Operation: Air carrier
- Make and model: Doug DC-9-32
- Registry model: [Doug DC-9-32](https://openairdocs.org/model/mcdonnell-douglas-dc-9-32) (OpenAirDocs)
- System (JASC): [2530 · Buffet/Galleys](https://openairdocs.org/jasc/2530)
- Part: Oven
- Condition: Malfunctioned
- Location: Cabin
- Part time: 54,009 hours
- Stage of operation: CL
- Nature of condition: B
- Precautionary procedure: H
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA980402012

## Discrepancy

(CAN) ELECTRICAL FUMES DETECTED ON CLIMB-OUT. ELECTRICAL FIRE DRILL CARRIED OUT.  GALLEY POWER SWITCHED OFF.  SMELL DISSIPATED. THE MIDDLE OVEN POSITION NR 16 FOUND TO BE THE CAUSE OF THE PROBLEM AND WAS ISOLATED.  OVEN RECEPTACLE CHANGED AND CHECKED SERVICEABLE.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.