# SDR CA981019029

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 22, 1998
- Submitted: March 26, 2000
- Operation: Air carrier
- Make and model: Doug DC-9-32
- Registry model: [Doug DC-9-32](https://openairdocs.org/model/mcdonnell-douglas-dc-9-32) (OpenAirDocs)
- Engine: Pwa JT8D7A
- System (JASC): [2161 · Cabin Temperature Controller](https://openairdocs.org/jasc/2161)
- Part: Controller
- Condition: Failed
- Location: Rt Pack
- Stage of operation: CL
- Nature of condition: B
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CA981019029

## Discrepancy

(CAN) ON DEPARTURE AT 2,500 FEET, THE RIGHT AIR CONDITION PACK OVERHEATED THEN FORWARD FIRE DETECTORS ANNUNCIATED, FLIGHT ATTENDANT REPORTED SMOKE IN CABIN, DECLARED EMERGENCY AND RETURNED TO BLOCKS . REPLACED AUTOMATIC CABIN TEMPERATURE CONTROLLER.

---