## Discrepancy

(CAN) THE 90 DEGREE HEAT DUCT ON THE RIGHT HAND OF THE COPILOT'S RUDDER PEDALS DIRECTS HOT AIR ONTO THE NR 2 COMM, AND DME COAXIAL WIRE BUNDLES.  OVER TIME , THIS CAUSED CABLE DAMAGE MELTING THE WIRE AND ALLOWING THE CENTER CONDUCTOR TO SHORT TO THE SHIELD.  DAMAGE LIMITED TO A SIX INCH AREA.  FLEET CAMPAIGN TO BE CARRIED OUT.

---