# SDR CALA2021011800050

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: January 16, 2021
- Submitted: January 18, 2021
- Operation: Air carrier
- Aircraft: [N829UA](https://openairdocs.org/aircraft/N829UA), registered now
- Make and model: Airbus A319-131
- Registry model: [Airbus A319-131](https://openairdocs.org/model/airbus-industrie-a319-131) (OpenAirDocs)
- Aircraft serial: 1211
- Aircraft time: 64,413 hours, 27,594 cycles
- System (JASC): [3350 · Emergency Lighting](https://openairdocs.org/jasc/3350)
- Part: Power Supply
- Part number: 32145410
- Part serial: 4952
- Condition: No Test
- Location: Emergency Lights
- Stage of operation: IN
- How discovered: C
- Nature of condition: L
- Precautionary procedure: K
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CALA2021011800050

## Discrepancy

A3NB-33-3-6012 EMERGENCY SYSTEM TEST FAILS, EPSU COMM EMERGENCY L ATA 33-51-38.  REFER TO PEMCO NR 10441.0024.  REMOVED AND REPLACED EPSU 11WL.  OPERATIONS CHECK GOOD, IAW A320 33-51-38, 33-51-00.  ADD FAULT: N ROTABLE PARTS CHANGE WAS INDICATED-TT 1212671 SN OFF 4952 POWER SUPPLY, C OFF 31-3350-9-9001 4952 ON 31-3350-9-9001 8328.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain, except the copies of manufacturers’ service documents, which belong to their rights holders.