# SDR CALA2025102910716

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: October 26, 2025
- Submitted: October 29, 2025
- Operation: Air carrier
- Aircraft: [N68817](https://openairdocs.org/aircraft/N68817), registered now
- Make and model: Boeing 737924ER
- Aircraft serial: 42747
- Aircraft time: 36,638 hours, 13,355 cycles
- System (JASC): [3610 · Pneumatic Distribution System](https://openairdocs.org/jasc/3610)
- Part: Sensor
- Part number: 1296663
- Part serial: 9019
- Condition: Faulted
- Location: Lt Engine
- Part time: 111,189 hours, 44,009 cycles
- Stage of operation: CR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CALA2025102910716

## Discrepancy

CHIME ALERTED LEFT ENGINE BLEED TEMP NEARING BLEED TRIP OFF, DURING CRUISE AND DESCENT. THE BLEED REPORT CAPTURED THAT THE PRE-COOLER OUTLET TEMPERATURE REACHED AS HIGH AS 490 Â°F, RESULTING IN A LOW BLEED DUCT PRESSURE OUTPUT OF 17 PSI. (SYSTEM HAS GONE INTO OVERTEMP PROTECTION MODE)   PERFORMED TEST ON LT PRE-COOLER CONTROL VALVE IAW AMM 36-12-00-700-801. CHECK PASSED.  REMOVED AND REPLACED 390 SENSOR IAW AMM 36-13-03. LEAK CHECK PASSED.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.