# SDR CALA2026062517327

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: June 23, 2026
- Submitted: June 25, 2026
- Operation: Air carrier
- Aircraft: [N665UA](https://openairdocs.org/aircraft/N665UA), registered now
- Make and model: Boeing 767322
- Aircraft serial: 29237
- Aircraft time: 96,679 hours, 20,039 cycles
- System (JASC): [2910 · Hydraulic System, Main](https://openairdocs.org/jasc/2910)
- Part: Filter Module
- Part number: 7586631
- Condition: Tripped
- Location: Rt Hyd System
- Stage of operation: CR
- How discovered: O
- Nature of condition: K, J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CALA2026062517327

## Discrepancy

RIGHT HYD QTY EICAS. PER NON NORMAL TURNED OFF RT ENGINE AND ELECTRIC PUMP. FLUID QTY LOSS STOPPED AT .44 LEAK CHECK CARRIED OUT. LEAKAGE FOUND FROM ONE OF THE DPI ON FILTER MODULE AND COMPONENTS FOR THE PRESSURE AND CASE DRAIN OF THE ENGINE-DRIVEN PUMP (EDP) IN THE RT SYS.  DPI REMOVED AND INSPECTION CARRIED OUT, FOUND PACKING DETERIORATED, REFER IPC 29-11-17-04 ITEM 265 FOR REFERENCE. HYD FILTERS ON R SYSTEM EDP MODULE REMOVED AND INSPECTED WITH NO CONTAMINATION FOUND. HYD FILTERS AND DPI ON R SYS EDP MODULE REPLACED IAW AMM 29-11-17/401. SUBSEQUENT LEAK CHECK FOUND NIL FURTHER DEFECT. HYD QUANT STAYED AT STABLE LEVEL WITH EDP ON OR ACMP ON. R HYD SYSTEM SERVICING CARRIED OUT IAW AMM 12-12-01-613-059.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.