# SDR CALA2026072017891

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: July 15, 2026
- Submitted: July 20, 2026
- Operation: Air carrier
- Aircraft: [N78003](https://openairdocs.org/aircraft/N78003), registered now
- Make and model: Boeing 777224
- Aircraft serial: 27579
- Aircraft time: 127,054 hours, 13,203 cycles
- System (JASC): [2421 · AC Generator-Alternator](https://openairdocs.org/jasc/2421)
- Part: Generator
- Part number: 1701768
- Part serial: 2680
- Condition: Faulted
- Location: Nr 2
- Part time: 30,838 hours, 3,395 cycles
- Stage of operation: CL
- How discovered: O
- Nature of condition: J
- Precautionary procedure: A
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CALA2026072017891

## Discrepancy

ELEC BACKUP GEN R EICAS STATUS RIGHT BACKUP GENERATOR OFF DUE TO A PROTECTIVE TRIP.   DB BACKUP CONVERTER R&R E2 BUG IAW AMM 24-25-01. SECOND QUALIFIED MECHANIC WITNESSED NEW BUG SHAFT PACKING REPLACED.   C/W IDT INSPECTION OF BUG FEEDER CABLE INSTALLATION IAW AMM 24-25-01 AND GMM 09-10-05 E2 BUG OPS AND LEAK CHECK STILL REQUIRED. POWERPLANT TEST 2, 5 AND 6 REQUIRED IAW AMM 24-25-01. CORRECTION ONLY POWERPLANT TEST 2 AND 5 REQUIRED FOR BUG ON E2. OPS & LEAK CHECK GOOD.

---