# SDR CALA2026090319226

- Type: Service difficulty report (as reported; unverified)
- Difficulty date: September 2, 2026
- Submitted: September 3, 2026
- Operation: Air carrier
- Aircraft: [N851UA](https://openairdocs.org/aircraft/N851UA), registered now
- Make and model: Airbus A319-131
- Registry model: [Airbus A319-131](https://openairdocs.org/model/airbus-industrie-a319-131) (OpenAirDocs)
- Aircraft serial: 1664
- Aircraft time: 73,609 hours, 33,286 cycles
- Engine: Iae V2522A5
- System (JASC): [2121 · Air Distribution Fan](https://openairdocs.org/jasc/2121)
- Part: Fan
- Part number: EVT3454HC
- Part serial: 3332
- Condition: Faulted
- Location: Zone 100
- Stage of operation: NR
- How discovered: O
- Nature of condition: J
- Precautionary procedure: O
- FAA source: FAA Service Difficulty Reporting System (https://sdrs.faa.gov/)
- Page: https://openairdocs.org/sdr/CALA2026090319226

## Discrepancy

VENT BLOWER FAULT ECAM ON GROUND. SWITCHING BLOWER TO OVERIDE  C AUSES CHEMICAL ODOR REMOVED BLOWER FAN REF AMM 21-26-51-000-001-A. REMOVED BLOWER FAN REF AMM 21-26-51-000-001-A. REMOVED AND REPLACED FAN AVIONICS FAN GROUND COOLING AMM 21-26-51/40.

---
OpenAirDocs.org is an independent research project of [Contrail Labs](https://contraillabs.com/). It is not affiliated with the FAA or the NTSB. Source documents are U.S. government works in the public domain.